Herunterladen Inhalt Inhalt Diese Seite drucken

Balluff BCM R15E-00 DI00 S4 Serie Betriebsanleitung Seite 90

Condition monitoring sensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BCM R15E-00 _ -DI00-_ _ , _-S4
Condition Monitoring Sensor
6
IO-Link interface (continued)
6.7
Device error messages
When erroneous accesses occur the device answers with
one of the error codes listed below.
Error code
Error message
0x8000 (32768)
Device application error – no details
0x8011 (32785)
Index not available
0x8012 (32786)
Sub index not available
0x8020 (32800)
Service temporarily not available
0x8021 (32801)
Service temporarily not available –
local control
0x8022 (32802)
Service temporarily not available –
device control
0x8023 (32803)
Access denied
0x8030 (32816)
Value out of range
0x8031 (32817)
Parameter value above limit
0x8032 (32818)
Parameter value below limit
0x8033 (32819)
Parameter length overrun
0x8034 (32820)
Parameter length underrun
0x8035 (32821)
Function not available
0x8036 (32822)
Function temporarily unavailable
0x8040 (32832)
Invalid parameter set
0x8041 (32833)
Inconsistent parameter set
0x8082 (32898)
Application not ready
Tab. 6-24: Error messages in accordance with IO-Link specification v
1.1.2
42
english

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis