IO-Link interface (continued)
6.2.7

Relative humidity

The sensor is equipped with humidity monitoring (index
0x2041 (8257)). The humidity (subindex 0x01 (1)) and the
minimum and maximum values since the last startup
(subindex 0x02 (2) and 0x03 (3)), since production
(subindex 0x04 (4) and 0x05 (5)) and since the last manual
reset (subindex 0x06 (6) and 0x07 (7)) are measured. The
values in index 0x2031 (8257), subindex 0x02 (2), 0x03 (3),
0x06 (6) and 0x07 (7) can be reset for all modules
simultaneously by means of a maintenance reset (see
Section System commands on page 41) or induvidually
for the humidity (see Section Device commands on page
41).
Index
Sub-
Access Description
index
HUMIDITY
1)
0x2041
0x01
Read
(8257)
(1)
only
0x02
Read
(2)
only
0x03
Read
(3)
only
0x04
Read
(4)
only
0x05
Read
(5)
only
0x06
Read
(6)
only
0x07
Read
(7)
only
HUMIDITY ALARM CONFIGURATION
0x2042
0x01
Read/
(8258)
(1)
Write
0x02
Read/
(2)
Write
0x03
Read/
(3)
Write
HUMIDITY ALARM STATUS
0x2043
0x01
Read
(8259)
(1)
only
0x02
Read
(2)
only
Tab. 6-11: Relative humidity
only for the BCM R15E-002-DI00-_ _ , _-S4
1)
26
english
1)
HUMIDITY – Current value in % RH
MINIMUM HUMIDITY SINCE STARTUP – Minimum
value since the last startup in % RH
MAXIMUM HUMIDITY SINCE STARTUP – Maximum
value since the last startup in % RH
MINIMUM HUMIDITY LIFETIME – Minimum value since
production in % RH
MAXIMUM HUMIDITY LIFETIME – Maximum value
since production in % RH
MINIMUM HUMIDITY SINCE RESET – Minimum value
since the last manual reset in % RH
MAXIMUM HUMIDITY SINCE RESET – Maximum value
since the last manual reset in % RH
1)
LOWER ALARM LEVEL HUMIDITY – Lower threshold
for humidity in % RH
UPPER ALARM LEVEL HUMIDITY – Upper threshold
for humidity in % RH
ENABLE ALARM HUMIDITY – Activates (True) or
deactivates (False) the sending of the IO-Link events
0x8CE5 and 0x8CE6 if one of the thresholds is
exceeded or underrun
1)
LOWER ALARM STATUS HUMIDITY – Lower threshold
underrun
UPPER ALARM STATUS HUMIDITY – Upper threshold
exceeded
A lower threshold (index 0x2432 (8258) subindex 0x01 (1))
and an upper threshold (index 0x2042 (8258)
subindex 0x02 (2)) can be defined for the relative humidity
module. The sensor recognizes when a threshold is
exceeded and sets the Boolean variables for
undershooting the lower threshold (index (0x2043 (8259)
subindex 0x01 (1)) or for exceeding the upper threshold
(index 0x2043 (8259) subindex 0x02 (2)). These Boolean
variables are available in the status bits of the process data
(see Section Process data on page 39).
Additionally, the sensor can trigger IO-Link events if a
threshold is exceeded. The sending of events (see
Tab. 6-21 on page 40) for monitoring the humidity can
be switched off (index 0x2042 (8258) subindex 0x03 (3)).
Data
type
float32
float32
float32
float32
float32
float32
float32
float32
float32
bool
bool
bool
Value
Default
range
value
5...95
5 [% RH]
[% RH]
5...95
95 [% RH]
[% RH]
True/False
True