Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Hours Counter - Balluff BCM R15E-00 DI00 S4 Serie Betriebsanleitung

Condition monitoring sensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BCM R15E-00 _ -DI00-_ _ , _-S4
Condition Monitoring Sensor
6
IO-Link interface (continued)
6.2.4

Operating hours counter

Operating hours (index 0x0057 (87)) are counted since the
last startup (subindex 0x01 (1)), since production (subindex
0x02 (2)) and since the last manual reset (subindex 0x03
(3)).
Index
Sub index
Access
OPERATING HOURS
0x0057
0x01 (1)
Read only
(87)
0x02 (2)
Read only
0x03 (3)
Read only
Tab. 6-8:
Operating hours counter
6.2.5
Boot cycle counter
The BCM counts every startup (index 0x0058 (88)) since
production (subindex 0x01 (1)) and since the last manual
reset (subindex 0x02 (2)).
Index
Sub index
Access
BOOT CYCLE COUNTER
0x0058
0x01 (1)
Read only
(88)
0x02 (2)
Read only
Tab. 6-9:
Boot cycle counter
24
english
Description
OPERATING HOURS SINCE STARTUP – Operating hours since the
last startup. Value in seconds.
OPERATING HOURS LIFETIME – Operating hours since production.
Value in seconds.
OPERATING HOURS SINCE RESET – Operating hours since the last
reset of the counter by means of a maintenance reset. Value in
seconds.
Description
BOOT CYCLE COUNTER LIFETIME – Number of application starts
since production
BOOT CYCLE COUNTER SINCE RESET – Number of application
starts since the last reset of the counter by means of a maintenance
reset
Data type
uint32
uint32
uint32
Data type
uint32
uint32

Quicklinks ausblenden: