Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch Diesel Set 3.1 Originalbetriebsanleitung Seite 25

Off-board-diagnose
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
3.5.6
Digital pressure display unit
The digital pressure display unit is designed for opera-
tion with 2 x Mignon batteries (AA, LR6) or 2 x Mignon
NiMh storage batteries (AA, LR6), 2500 mAh and has
an operating time of about 50 hours with fully charged
batteries / storage batteries (depending on the aging
process of the batteries / storage batteries).
The digital pressure display unit switches off automati-
cally about 5 minutes after a button was last actuated.
Characteristic
Measuring range
Display accuracy
Battery/storage battery
* not included in scope of delivery
i
The illumination level and on-period have been set
very low in order to achieve a long operating time
with a set of storage batteries or batteries. It is most
effective when the light level of the surroundings is
low (e.g. in a vehicle).
i
The additional illumination switches off automati-
cally after 15 seconds and can be reactivated by
pressing a button briefly.
!
Prevent moisture from getting inside.
Front view
Abb. 10: Digital pressure display unit – front of the unit
1 Display
2 Power key (ON/OFF), operation
Function
Operation
On
Press button for 1 second.
Off
Press button for 3 seconds.
Display illumination
Press button for 0.5 seconds.
Switching between
Press button for 2 seconds.
MPa - bar*
Robert Bosch GmbH
Value
0...200 MPa / 0...2000 bar
+/- 1%
2 x Mignon battery (AA, LR6) or
2 x Mignon NiMh storage battery
(AA, LR6), 2500 mAh *
Product description | Diesel Set 3.1 | 25
*Conversion factors:
1 bar = 0.1 MPa = 100 kPa = 100 000 Pa;
1 MPa = 10 bar
Rear view
Abb. 11: Digital pressure display unit – back of the unit
1 3-pin threaded connection for connecting cable
2 Storage-battery compartment with 2 x AA storage batteries or
equivalent AA batteries
!
Ensure correct polarity when installing the batteries/
storage batteries!
i
If [BATT LOW] or [BATT OFF] appears on the dis-
play, the storage batteries/batteries are empty.
Remove empty batteries from the pressure display
and replace with new batteries.
i
If storage batteries are being used, remove the
storage batteries from the pressure display unit and
charge them with a commercially available charger.
We recommend use of a charger with the following
technical specifications:
Characteristic
Storage-battery charger
Functions
Value
Microprocessor-controlled, for
Mignon NiMh storage batteries
(AA, LR6)
- Delta-U charge monitoring
- Discharge function
- Defective storage battery de-
tection
- Overheating protection
|
1 689 989 210
2015-10-20
en

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis