Herunterladen Inhalt Inhalt Diese Seite drucken

Error Messages; Selftest Routine, Diagnostic Program; Power Supply; Environmental Conditions - Philips PM 5330 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
PM 5330
CHARACTERISTICS
4 — 17
LEFT IN
RIGHT IN
PILOT OUT
MPX OUT
RDS OUT
4.13
ERROR MESSAGES
BNC sockets, LF inputs for external
stereo modulation, Zo =
1 MS2
BNC socket, output pilot
signal 19 kHz, Zo = 200 52
BNC socket, output stereo multiplex
signal, Zo = 5 S?
BNC socket, output RDS/ARI
signal, Zo <12 2
Unallowed settings are indicated by flashing of the incompatible settings or their combinations.
4.14
SELFTEST ROUTINE, DIAGNOSTIC PROGRAM
After POWER ON the instrument performs a selftest routine, whereby the PROMs, RAMs, and
EEPROMs are tested. After this the software version is indicated on the display.
4.15
POWER SUPPLY
nominal values
ac mains voltage
100/120/220/240 V
selectable at mains input
connector
reference value
220 V
±2
nominal operating range
operating limits
—"
nominal frequency range
— operating limits
power consumption
±10
±10
50 — 60 Hz
47.5 Hz, 63 Hz
66 W
4.16
ENVIRONMENTAL CONDITIONS
of nominal value
of nominal value
The environmental data mentioned in this manual are based on the results of the manufactur-
er's checking procedures.
Details on these procedures and failure criteria are supplied on request by the PHILIPS organi-
sation in your country, or by PHILIPS, INDUSTRIAL ELECTRONICS DIVISION, EINDHOVEN,
THE NETHERLANDS.
ambient temperature:
reference value
rated range of use
limit range of operation
storage and transport range
+23 °C ±2 °C
+ 5 °C...+40 °C
+ 5 °C...+45 °C
—40
°C...+70 °C

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis