OPERATING INSTRUCTIONS
PM 5330
S
~R.as
ARI
ll.~ ~
~.i.1 ME 12
REMOTE LLO EXT REF
O f MOD
ID.O.L7.
kHz ~
DEVT m
Y.
~.
~.
%kHz
Connections:
Description
Function
COUNTER IN
MOD IN
RF OUT
Zo SO ,{Z
®R~D~S :Radio Data System (option)
combined with two digits shows
selected data record 1 - 10;
20 records for instruments
with remote control
ARI
Autofahrer Rundfunk Infor-
mation (option)
IB
DK
combined with 1 ~h digits (USA)
ME t~2
resp. letters A - F (Germany)
shows the area code;
D
= area identification
switched off
DK = announcement ident.
on or off (Germany)
ME 1 /2 =message signal 1 or 2,
on or off (USA)
-
REMOTE : shows remote control
-
LLO
: shows that the key LOCAL
is disabled via remote control
-
EXT REF : shows that external
reference frequency is applied
-
display of modulation parameters:
f
SWP
: sweep frequency, Hz
(sweeps per second)
f MoD
:modulation frequency, kHz
WIDTH
: sweep width kHz or MHz
DEV
: frequency deviation for FM
m
:modulation depth for AM
-
display of counter impedance
50 ,f2,/1 M.fZ: impedance of counter input
signal input for frequency counter
input for external modulation signals
RF output
(reverse power protected, max. load 15/50 W)