3 - 3
3.5
OPERATION
3.5.1
Design of Display Field and Keyboard (see Appendix, Figure 1)
The display field consists of four rows for following indication (from top to bottom)
-
frequency, max. 7~/z digits
-
unit MHz, kHz
-
COUNTER for frequency counter function
-
special functions SPCL, 2 digits
_
-
output level, max. 3~h digits
-
unit dBm with negative sign for -dBm; mV/µV;
unit dBm can be changed to dBmV or dBµV by SPECIAL function
-
ENTER to indicate the input mode
-
RF OFF to indicate switched -off output signal
-
ADDRESS in combination with 2 digits
-
modulation modes:
SWP AM EXT FM EXT STEREO L=-R* RDS* ARI*
* indicated only if option is available:
—'
STEREO L=-R
RDS -
Radio Data System
ARI
-
'Autofahrer Rundfunk Information' ; traffic announcements
-
REMOTE for identification of remote operation
-
LLO (local lockout) to indicate the LOCAL key is disabled
-
EXT REF if external reference frequency is applied
-
PILOT ON OFF PREEMPHASIS 75/50 µs OFF combined with stereo (option) ;
indicates stereo parameters
-
2 digits for datasets in combination with RDS (option)
-
1~h digits resp. letters A-F DK MK 1/2 indication of ARI modes (option)
-
modulation parameter, max.:
2 digits for sweep frequency, unit Hz
3 digits for modulation/audio frequency, unit kHz
3 digits for sweep width, unit kHz or MHz
3 digits for modulation depth (%) and frequency deviation (kHz)
The symbol "►" in front of the single rows shows that this section is ready for input or
selection of data respectively parameters.
The symbol "O" in the first or second row flashes to show that the step width can be set for
frequency- respectively output level-stepping.
~'-
The symbol "o" indicates whether the RF frequency, output level, modulation /audio fre-
quency, depth or deviation can be altered by the rotary knob.