If the LED Power flashes red and green alternately, the upload has
been unsuccessful and must be restarted. In order to perform the
upload, it is necessary to change over to a special page:
Enter /main.htm in (e. g. 192.168.0.12/main.htm) in the
address field of the browser behind the IP address of the unit.
Restart the upload process.
Configuration download:
You can store the configuration setting of the device on a PC.
Click on the button Download. A dialog window is opened.
Follow the instructions in the dialog window to save the settings.
Configuration upload:
You can upload stored configuration settings from a PC.
Enter the complete directory path of the file to be uploaded or click
on the button Durchsuchen... to select the desired file.
Ensure that the download file originates from the same type of
device that you want to reconfigure.
Click on the button Upload to start the transmission of the file to the
device.
After a few seconds the message Configuration upload finished.
State: Configuration upload ok. (system must be rebooted) will
be displayed and the countdown for the reconnection is shown.
Restart the device.
At the next call-up of the configuration page Software update the
message Configuration upload ok confirms the successfull com-
pletion of the upload. If the message Configuration upload failed
is displayed the file was not correctly uploaded (e.g. because it did
not originate from the same type of device). Repeat the upload pro-
cedure, possibly with a different file.
Configuration with web browser
75