Herunterladen Inhalt Inhalt Diese Seite drucken

Accuracy Of Measured Values - Power One AURORA PVI-10.0-I-OUTD-400 Installations- Und Bedienungshandbuch

Photovoltaik-wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Use and installation manual
(PVI-10.0/12.0-I-OUTD(-S)-400 Rev:1.3)
6.2

Accuracy of measured values

Every measurement is subject to errors.
The tables below outline the following information for each
measurement:
units of measurement;
range;
resolution.
Input voltage
PV No. 1
Input voltage
PV No. 2
Input current
PV No. 1
Input current
PV No. 2
Power supplied
PV No. 1
Power supplied
PV No. 2
Output voltage
Output current
Output power
Frequency
Name of
Unit of
measured
measur
variable
ement
VP1
Vdc
VP2
Vdc
IP1
Adc
IP2
Adc
Pin1
W
Pin2
W
Vout
V
Iout
A
Pout
W
Freq
Hz
Resolution
Display
Value
1 V
160mV
1 V
160mV
0.1 A
7mA
0.1 A
7mA
1 W
6W
1 W
6W
1 V
200mV
0.1 A
20mA
1 W
9W
0.01
0.01
86
97
Page
of
Nominal
precision
2%
2%
2%
2%
2%
2%
2%
2%
2%
0.1%