Herunterladen Inhalt Inhalt Diese Seite drucken

Start-Up Using The Side Button; Shut-Down Procedure - Power One AURORA PVI-10.0-I-OUTD-400 Installations- Und Bedienungshandbuch

Photovoltaik-wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Use and installation manual
(PVI-10.0/12.0-I-OUTD(-S)-400 Rev:1.3)
4.2

Start-up using the side button

If DC voltage is not present but the AC grid is properly connected and you wish to
start the inverter, press the side button shown in Fig. 18 for more than 2 seconds. A
beep indicates that the system has acknowledged the input given by pressing the
button.
The inverter will remain switched on for 10 minutes, allowing every type of
control on the display (statistics, settings, etc.). The inverter will not connect to the
grid until a valid and stable DC is present for input. When the inverter is started up
with no DC voltage, its consumption is less than 20W.
Fig. 18 - Button for starting up the inverter from the grid
4.3

Shut-down procedure

The inverter can be shut down in three different ways:
1) Disconnect DC and the AC grid by disconnecting their disconnectors (in
any order). The inverter will shut down after a few seconds, which are
required in order to discharge the internal capacities.
2) Disconnect DC by disconnecting the relative disconnector, and wait for
the set UV prot Time (see paragraph 5.5.6.11).
3) Disconnect the grid by disconnecting its disconnector, with a DC input
lower than 80 Vdc.