To perform the repair of damaged parts.
FAILURE
Compressor does not start
Compressor often switches
on
Prolonged
running
of
compressor
Compressor is noisy
(knocking, metal noises)
Suction unit does not work,
or works intermittently
Suction unit is not sucking,
or is sucking insufficiently,
motor works
Dryer doesn´t dry
(condensed water in the
tank)
The internal surfaces of the air tank must be cleaned and all condensed liquid must be removed after a dryer
failure.
Check the dew point of the air leaving the air tank (see Chapter 5 - Technical Data) in order to protect
connected equipment from damage!
11/2015
POSSIBLE CAUSE
No voltage in pressure switch
Disconnected winding of motor, damaged thermal
protection
Faulty capacitor
Seizure of piston or another rotary part
Pressure switch does not switch on
Air leak in pneumatic distribution system
Leaking check valve
Greater volume of condensed liquid in pressure
vessel
Air leak in pneumatic distribution system
Worn piston ring
Contaminated input filter and prefilter
Contaminated filter in dryer
Defective solenoid valve
Damaged bearing of piston,
bearing
Loose or cracked spring
No voltage in suction unit clamp
Exhauster overheating
(thermal protection switched off)
Suction line leaking, foreign object trapped in suction
piping, blocked exhaust line
inoperative cooler ventilator
Damaged dryer
Dirty automatic condensate drain on filters
Dirty filter and micro-filter elements
Check voltage in socket
Check fuse – replace faulty one
Loosen terminal – tighten it
Check power cord – replace faulty one
Replace motor or re-wind it
Replace capacitor
Replace damaged parts
Check the function of pressure switch
Check pneumatic distribution system – seal
loose joint
Clean valve, replace seals, replace valve
Drain condensed liquid
Check pneumatic distribution system
loose joint
Replace worn piston ring
Replace contaminated filters with the new ones
Replace the output filter in a chamber or also its
refill if it gets decomposed or if it is very dusty
Repair or change the valve
piston rod, motor
Replace damaged bearing
Replace damaged spring
Check voltage in the socket
Check fuse
Loose clamp – tighten
Check the power cord
Methodically test the wiring circuit
The check of functionality of housing ventilator –
replace the non-functioning one
Check of the clearness of sucking and
exhausting tract - (remedy hose cranks and
remove foreign objects)
Check/replace damaged suction line,
check/clear suction line of foreign objects,
unblock exhaust line
replace ventilator
check supply of electric energy
Replace dryer
clean / replace
Replace old elements with new elements