2) Control via digital contacts:
PIN6, PIN7, PIN8, PIN11 digital input, clean contact (maximum voltage 5Vdc, maximum current 1mA); the
contact is configurable if normally closed or open (see par. 5.7 "INPUT TYPE")
PIN 1: A RUN/STOP digital input, with clean contact (maximum voltage 5Vdc, maximum current 1mA); the
closed contact means "run", the open contact means "stop".
PIN 3: Earth contact for the connection of all inputs.
For pump Versions with 5-pin connector, the E.ADAPT module is used for digital contacts:
The operation can be with auxiliary inputs enabled or in override/priority with respect to the programming of the timers.
This allows us to control the pump as a simple slave with respect to the external control panel or as a semi-slave
where the external controls have priority over the programming of the pump but do not exclude it completely.
The inputs are not opto-isolated.

2.5.2 Output

The output is made from a relay NO and NC (clean contact), with the following electrical characteristics.
Max. bearable voltage [V]
Max. bearable current [A]
Max. bearable power
ENGLISH
Characteristics of the output contacts
24Vac / 24Vdc
2A
1 A
2.5VA / 2W
Table 2 - Output contact
-> resistive load
-> inductive load
47