2.5 Electrical connections for auxiliary inputs and outputs

The pump has a connector for configurable user inputs and outputs.
The following figure shows the connector contacts, while the table below sums up the associated signals:

2.5.1 Inputs

The auxiliary inputs can be configured for different types of control:
1) Digital/analog control:
PIN 1: digital input, clean contact (maximum voltage 5Vdc, maximum current 1mA); the contact is configurable if
normally closed or open (see par. 5.7 "INPUT TYPE")
PIN 2: An input for an external analog signal, configurable as 0-10V or 4-20 mA .
PIN 3: Earth contact for the connection of all inputs.
The following figure shows the relationship between the analog signal on input and the setpointSP to be activated.
PIN NAME
Wire Color
1
IN0_D
RED
2
IN0_A
BROWN
3
GND
BLACK
4
OUT COM
BLUE
5
OUT NO
WHITE
6
IN1_D
PINK
7
IN2_D
GREEN
8
IN3_D
YELLOW
9
OUT NC
VIOLET
10 GND
GREY
11 IN4_D
RED/BLUE
12 N.U.
PINK/GREY Not used
ENGLISH
Figure 4
SIGNAL DESCRIPTION
Digital Input 0 (start/stop)
Analog Input 0 (0-10V or 4-20mA)
Earth
Output relay: Common Contact
Output relay: Contact Normally Open
Digital Input 1
Digital Input 2
Digital Input 3
Output relay: Contact Normally Closed
Earth
Digital Input 4