Herunterladen Inhalt Inhalt Diese Seite drucken

Functional Description; Power Supply And Enabling Signals; Detergent Metering - ECOLAB CDI01 Bedienungsanleitung

Dosiergerät mit integriertem induktivem leitfähigkeitsregler
Vorschau ausblenden Andere Handbücher für CDI01:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6

Functional description

6.1

Power supply and enabling signals

A internal transformer supplies power to the main board of the CDI 01.
fig. 6.1
Designation
Pos.
8
Connection cable - conductivity sensor
9
Conductivity sensor
10
Tank connection
11
Solution washing tank
12
Transfer pump
External enabling signals
13
- Metering enable
- Pre-metering
6.2

Detergent metering

The detergent concentration in the wash solution tank is taken from the inductive
conductivity sensor during the whole cleaning process.
The concentration is controlled by a micro processor on the PCB of the CDI 01 unit.
If the concentration falls below the necessary level, the detergent will be sucked out of the
chemical reservoir to be metered into the solution tank.
As the pre-adjusted concentration level is almost reached, the system/dosing switches over
to "pulse-pause state", until the pre-adjusted concentration is finally reached. Higher
concentrations are limited by a self learning system (fuzzy logic).
417101089_CDI01.doc
Pos. Designation
only at:
123524
123526
123528
- 44 -
Metering pump with integrated
1
inductive conductivity controller
2
Metering pipe
3
Suction pipe
4
Chemical empty signal
5
Suction lance
6
Chemical reservoir (drum)
Main supply cable
art. no.
Designation
123519
&
240/ 2 x 12VAC, 15VA
123524
7
123525
&
120/ 2 x 12VAC, 30VA
123526
123527
&
24/ 2 x 12VAC, 15VA
123528
Rev.: 4-01/10

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis