Technical data, display

Display
Dimensions (L x W x H)
Operating temperature
range
Storage temperature
range
Interfaces
Truma CP plus VarioHeat
Truma CP plus
VarioHeat CI-BUS
Power supply
Current consumption at
rated voltage 12 V
Quiescent current
consumption
Weight
Subject to technical changes.

Maintenance

The Truma CP plus VarioHeat control panel is maintenance-
free. In order to clean the front panel, use a damp, non-scour-
ing cloth. If this is not sufficient, use a neutral soap solution.
Truma CP classic VarioHeat analogue
control panel (optional)
a
b
Figure 33
a = "Heating" control knob
Green LED "Operation"
Red LED "Fault / Warning"
b = Rotary switch
c = "Heating" rotary switch
Large flame symbol "eco"
Small flame symbol "night"
d = Rotary switch "Off"
e = Rotary switch "Vent"
Full load (large symbol)
Partial load (small symbol)
eco
Automatic control of the fan, depending on the heating power /
optimised to the current heating requirement
night
Heater running only at partial load. Might not be possible to
reach the set room temperature (depending on the vehicle
size and outside temperature).
Switch the heater on
– Set the desired room temperature at the control knob (a).
– Set the rotary switch (b) to the desired output (c).
Switch the ventilation on
– Set the rotary switch (b) to the desired output (e).
LCD, monochrome, with
background lighting
92 x 103 x 40 mm
-25 °C to +60 °C
-25 °C to +70 °C
TIN bus
TIN bus, CI BUS
8 V – 16.5 V
max. 65 mA (100 % back-
ground lighting)
6.5 mA – 10 mA (stand-by)
max. 3 mA (Off)
approx. 100 g
VarioHeat
e
d
c
Switching off
Set the rotary switch (b) to the centre(d). If the heater is
turned off after heating, the fan may still run to utilise the re-
sidual heat.
Green LED "On"
(beneath control knob)
When the device is on (heating or ventilation), the green LED
must light up (the fan is on). If the LED does not light up,
check the (main) switch if necessary. Please observe the re-
spective vehicle manufacturer's instructions.
Red LED "Fault / warning"
If there is a fault / warning, the red LED flashes. In each case,
the fault is reset by switching off and then switching back on
again. Following a reset, it can take some time until the green
LED lights up again.
A flashing code is output in the event of a fault / warning.
The Truma CP classic VarioHeat troubleshooting guide
enables the cause and remedy to be determined.
Maintenance
The Truma CP classic VarioHeat control panel is maintenance-
free. In order to clean the front panel, use a damp, non-scour-
ing cloth. If this is not sufficient, use a neutral soap solution.

Disposing of the VarioHeat

The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Regulation) must be observed.

VarioHeat fuse

The device fuse is located on the electronic control unit and
can only be changed by an expert.
Device fuse (F1):
10 AF – quick – (EN 60127-2-3)
The fine fuse must always be replaced with a fuse of the same
type.

Accessories

Cowl cover
39141-00 creamy white
39141-01 black
39141-02 bianco
25