10. Specifications
10-1. LT10A/LT11A (Specifications)
Model
LT10A-105
LT11A-101
Item
Display
Measuring unit input
I/O connectors
*1
BCD
*2
*3
RS-232C
RS-TRG
*4
Reset function
Preset function
Conparetor function
Three-level comparator
Comparator value set with keys on the front panel.
Result evaluation: LED and I/O connector output (photocoupler)
∗ ∗ ∗ ∗ ∗ 1: I/O connector
Input : Reset, peak-hold start, peak-hold pause, RS trigger (RS-
232C models only)
Output : Result evaluation (photocoupler)
LT10A / LT11A Series
105B
101B
1 channel
—
\
—
—
Reset key or external input (I/O connectors)
BCD terminal
—
Preset value set with preset key, recalled with reset key.
Recalled with BCD Set or recalled with
—
reset terminal
RS-232C command
Up to 4 values
Set with RS-232C
can be set for
command
comparator (key
—
input).
Switched with
BCD terminal.
105C
205
101C
201
5 digit backlit LCD, mode display
\
—
—
\
\
RS-232C
—
command
—
—
∗ ∗ ∗ ∗ ∗ 2: BCD (36 pin half-pitch connector)
Input : Reset, peak-hold start, comparator value selection (4 settings)
Output : five digits (open collector)
One of current value/maximum value/minimum value/peak-to-peak
value selected and output.
Alarm output
205B
205C
201B
201C
2 channel
\
—
—
\
—
\
RS-232C
BCD terminal
command
Recalled with BCD Set or recalled with
reset terminal
RS-232C command
Up to 4 values
Set with RS-232C
can be set for
command
comparator (key
input).
Switched with
BCD terminal.
41