Herunterladen Inhalt Inhalt Diese Seite drucken

Result Evaluation; Peak-Hold Function - Sony LT10A Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4-3-3. Result evaluation

• Go/No Go test is carried out by comparing data from the
current measuring mode (current value, maximum value,
minimum value, or peak-to-peak value) to the comparator
upper and lower limits.
• This result is displayed on the front panel and output from
the I/O connector (See "6. I/O connector".).
Result
Display
>
High
Data > upper limit
Upper limit > data > lower limit
\
Go
?
Low
10
(E)
Condition
=
=
Lower limit > data

4-3-4. Peak-hold function

• Stores the maximum, minimum, and peak-to-peak
(maximum–minimum) values of the measured values.
• The above mentioned measuring mode is set using the
keys on the front panel.
• The device starts storing values either when a start signal
is supplied to the start/latch pins (channel A: pin 2,
channel B: pin 4 ) of the lower 7-pin I/O connector
(common) (See "6. I/O connector".) or when the reset key
has been pressed.
Operation
I/O connector (common) A CH:
starts on "L" (ON) signal from pin
2; I/O connector (common) B
CH: starts on "L" (ON) signal
from pin 4.
Reset key is pressed
Result
Starts storing from the current
value.
Starts storing from zero.
When a preset value is set the
device starts storing from the
preset value.
LT10A / LT11A Series