Herunterladen Inhalt Inhalt Diese Seite drucken

Peak-Hold Pause Function - Sony LT10A Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4-3-5. Peak-hold pause function

• Pause the storing of the maximum, minimum and peak-
to-peak (maximum-minimum) values of the measured
values.
• When the peak-hold function is to be paused, set the
pause pin of the lower 7-pin I/O connector (common) to
ON; to resume storing, set it to OFF.
7
6
5
4
3
2
1
7
DC IN
1
LT10A / LT11A Series
6
5
4
3
2
1
Common
I/O connector
2
3
4
5
6
7
5
PAUSE (B)
4
START (B)
3
PAUSE (A)
START (A)
2
Peak value data update stop (pause)
When pause is ON
The peak value updating is stopped. The current value is
constantly updated.
If the maximum value mode, minimum value mode or peak-
to-peak value mode is set as the measuring mode, the Go/
No GO judgment output and the output data are not
updated even when the measuring unit is operated.
When pause is OFF
The peak values are constantly updated.
Maximum value
Current value
Pause ON Pause OFF
11