4. Parameter Description
Torque Level output D1
GB
Speed Level output D2
Rated Motor Power
Rated Motor Speed
Rated Motor Current
Rated Motor Frequency
GB 30
Defines the torque level for the digital output D1.
Adjustment Range: 0...1000 Nm
Resolution:
Factory setting:
max. Tolerance approx. ±30 % in the base speed range
(In the field weakening range larger tolerances are possible.
also see reference on page GB 15)
During open-loop operation (CP.32 = 0) the value for the motor
torque is set at 0.
Defines the speed level for the digital output D2.
Adjustment Range:0...9999,5 rpm
Resolution:
Factory setting:
The rated motor power of the connected motor must be adjusted in
CP.25.
Adjustment Range: 0,01...75 kW
Resolution:
Factory setting:
dependent on size
The rated motor speed of the connected motor must be adjusted in
CP.26.
Adjustment Range:100...6000 rpm
Resolution:
Factory setting:
dependent on size
The rated current of the connected motor must be adjusted in
CP.27.
Adjustment Range:
depend. on size
Resolution:
Factory setting:
dependent on size
The rated frequency of the connected motor must be adjusted in
CP.28.
Adjustment Range: 20...300
Resolution:
Factory setting:
dependent on size
0,1 Nm
0 Nm
0,5 rpm
0 rpm
0,01 kW
1 rpm
0,1
A
Hz
1
Hz

Quicklinks ausblenden: