3. Operation

3.1 Keyboard

GB
GB 14
When KEB COMBIVERT F4 is started, the value of parameter CP.1
is displayed (actual speed display).
Use the function-key
to change between
parameter value and
parameter number.
With UP ( ) and
DOWN
(
)
the
parameter number,
or with changeable
parameters,
the
value is increased/
decreased.
The adjusted value is not immediately accepted in the ENTER
parameters. When this type of parameter is changed, a point
appears behind the last digit. The adjusted parameter is accepted
and permanently stored when ENTER is pressed (Point deleted).
Error
If a disturbance occurs during operation, the actual display is
overwritten with the error message. Press ENTER to reset the error
message.
Use the ENTER key to reset the error message in the actual display.
In the status display (CP.2) the error will still be shown.
To reset the error yourself, remove the cause of the error and do a
reset on terminal X2.2, or a power-on-reset.