Offset REF 1
4. Parameter Description
Makes it possible to shift the speed setpoint curve.
Adjustment Range: -100...+100 %
Resolution:
Factory setting:
-10 V
Examples:
Curve 1: CP.16 = 0% (Standard adjustment)
0V = 0 rpm
Direction of rotation "forward": n
Direction of rotation "reverse": n
Curve 2: CP.16 = -40%
0V = -40 % of n
"forward"
max
Direction of rotation "forward": n
Direction of rotation "reverse": maximum 60% of n
Curve 3: CP.16 = +70%
0V = 70 % of n
"reverse"
max
Direction of rotation "forward": maximum 30% of n
Direction of rotation "reverse": n
0,1 %
0 %
2)
n
max
"forward"
40 %
-4 V
+7 V
70 %
n
max
"reverse"
is reached at +10V
max
is reached at -10 V
max
is reached at 60% of +10V
max
is reached at 30% of -10V
max
ANTRIEBSTECHNIK
1)
GB
3)
+10 V
possible
max
possible
max
GB 25