4. Parameter Description
Behaviour at External Fault
GB
GB 24
This parameter determines how the drive reacts to an external error
(digital Input I3).
Adjustment Range:
Resolution:
Factory setting:
Note:
ENTER-Parameter
Value Error / Status
massage
0
E.EF
1
A.EF
2
A.EF
3
A.EF
4
A.EF
5
A.EF
6
none
Quick stop
0...6
1
0
Response of the drive
modulation immediately switched off
! To restart remove error and activate
Reset !
quick stop / modulation switched off
after speed 0 is reached
! To restart remove error and activate
Reset !
quick stop / holding tourqe at speed 0
! To restart remove error and activate
Reset !
modulation immediately switched off
! Automatic restart , when error is no
longer present !
quick stop / modulation switched off after
speed 0 is reached
! Automatic restart , when error is no
longer present !
quick stop / holding tourqe at speed 0
! Automatic restart , when error is no
longer present !
no effect on the drive
! Fault is ignored !
⇒ ⇒ ⇒ ⇒ ⇒
deceleration at the torque limit
(CP.9)