Herunterladen Inhalt Inhalt Diese Seite drucken

KEB COMBIVERT F4-F Betriebsanleitung Seite 64

Vorschau ausblenden Andere Handbücher für COMBIVERT F4-F:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. Parameter Description
Maximum Setpoint Speed
GB
Jog-Speed
GB 22
Defines the maximum setpoint speed.
Adjustment Range: 0...6000 rpm
Resolution:
Factory setting:
Analog setpoint
[rpm]
CP.10
0
+10
Only the reference speed is limited by this
parameter. The actual speed can exceed this value
because of control oscillations or a fault in the
speed detection.
Specifies a jogging speed (fixed speed), which can be activated by
the digital inputs I1 (forward) or I2 (reverse). If both rotations are
simultaneously preset, 'forward' has priority.
Adjustment Range: 0...6000 rpm
Resolution:
Factory setting:
Function:
• I1 or I2 active ⇒ The drive runs with an adjusted jogging speed.
- The original direction of rotation, speed, acceleration and
decleration times do not have a function!
- ACC and DEC times only have limited functions (see the
following table)!
- If the jogging speed entered is too high, the adjusted value is
internally limited onto the maximum permissible motor speed!
- The software limit switches (see CP.35) remain active!
• I1 and I2 not active ⇒ The drive runs with the analog reference
0,5 rpm
2100 rpm
Analoge setpoint presetting: REF 1
terminals X2.14 + X2.15
! see also parameter CP.36 !
U [V]
(REF 1)
0,5 rpm
100 rpm
speed.