3.2. Parameter Summary

Parameter
Parameter Describtion
Number
CP.0
Password Input
CP.1
Actual speed display
CP.2
Status display
CP.3
Apparent motor current
CP.4
Max. apparent motor current
CP.5
Actual torque display
CP.6
Speed reference display
CP.7
Acceleration time
CP.8
Deceleration time
CP.9
Torque limit
CP.10
Maximum setpoint speed
CP.11
Jogging speed
CP.12
P-factor speed controller
CP.13
I-factor speed controller
CP.14
Encoder 1 (inc/r)
CP.15
Behaviour at external fault
CP.16
Offset REF 1
CP.17
Zero point hysteresis REF 1
CP.18
Function output A1
CP.19
Gain output A1
CP.20
Gain output A2
CP.21
Output condition D1
CP.22
Output condition D2
CP.23
Torque level D1
CP.24
Speed level D2
CP.25
Rated motor power
CP.26
Rated motor speed
CP.27
Rated motor current
CP.28
Rated motor frequency
CP.29
Rated motor cos (Phi)
CP.30
Rated motor voltage
CP.31
Load motor dependent parameter
CP.32
Speed control on/off
CP.33
Boost
CP.34
Change encoder 1 rotation
CP.35
Reaction to limit switch
CP.36
Aux function
1)
Resolution means the program internal resolution of parameters.
The accuracy of the detection / calculation of the parameter values may be worse than the resolution.
2)
See table for parameter values that are dependent on the size (page GB 35)!
Due to the calculation / measuring accuracies, tolerances with the current and torque displays as well as with
the switching levels and limitations, must be taken into consideration. The given tolerances (see parameter
description) refer to the respective maximum values with the dimensioning KEB COMBIVERT: Motor = 1:1.
Dependent on the data from the motor manufacturer, larger tolerances at the torque displays are
possible, due to the usual variations in the machine parameters and temperature drifts.
3. Operation
Adjustment
Range
0...9999
1)
1)
1)
1)
1)
0...320
s
0...320
s
2)
0...5 x M
Nm
N
0...6000 rpm
0...6000 rpm
0...65535
0...65535
256...10000
0...6
-100...+100
%
0...10
%
0...6
-20...+20
-20...+20
0...20
0...20
1)
0...50 Nm
1)
0...9999,5 rpm
2)
0,01...75
kW
2)
100...6000 rpm
2)
0,1...50
A
20...300
Hz
2)
0,05...1
100...400
V
0...2
0...1
0...25
%
0...1
0...6
0...5
ANTRIEBSTECHNIK
Resolution
Factory Setting
1
0,5 rpm
0,1
A
0,1
A
0,1 Nm
0,5 rpm
0,01
s
0,01
s
0,1 Nm
dependent on size
0,5 rpm
0,5 rpm
1
1
1
1
0,1
%
0,1
%
1
0,01
0,01
1
1
0,1 Nm
0,5 rpm
0,01
kW
dependent on size
1 rpm
dependent on size
0,1
A
dependent on size
1
Hz
dependent on size
0,01
dependent on size
1
V
1
1
0,1
%
1
1
1
GB
2,0
s
2,0
s
2100 rpm
100 rpm
400
200
2500
0
0
%
0,2
%
1
1
1
20
18
0 Nm
0 rpm
400
V
0
0
2
%
0
6
0
GB 15