4. Parameter Description
A
b
n
o
r
m
a
GB
l
S
t
o
p
p
i
n
g
Apparent Motor Current
Max. Apparent Motor Current
Actual Torque Display
GB 18
Base-Block
– The Base-Block-Time (motor suppression time)
Time
runs out. The power transistors are locked.
external
– The external fault is triggered (terminal X2.7).
fault
The drive's response to external errors is
adjusted in parameter CP.15.
Prohibited
– Rotation release on terminal X2.3 is missing:
rotation
Drive does not start with positive setpoint and/
forward
or decelerates until standstill.
See also parameter CP.35
Prohibited
– Rotation release on terminal X2.4 missing:
rotation
Drive does not start with negative setpoint and/
reverse
or decelerates until standstill.
See also parameter CP.35
Displays the actual apparent current in ampere.
Resolution: 0,1 A
max. tolerance: approx. ±10 %
Displays the maximum apparent motor current, which is measured
during operation. The display is in ampere.
During operation, using UP ( ) or DOWN ( ) you can reset the
peak value. The peak value is deleted when the unit is POWER OFF.
Resolution: 0,1 A
max. tolerance: approx. ±10 %
Displays the actual torque in newtonmeter.
Resolution: 0,1 Nm
max. tolerance: approx. ±30 % in base speed range
(In the field weakening range larger tolerances are possible.
also see reference on page GB 15)
During open-loop operation (CP.32 = 0) value 0 is always shown.