Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Of Power Circuit; Terminal Strip X1A; Wiring Instructions - KEB Combivert F5 Installationsanleitung

Vorschau ausblenden Andere Handbücher für Combivert F5:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation and Connection
3.3

Connection of Power Circuit

3.3.1

Terminal Strip X1A

++
L1
N/L2
L3
Terminal strip X1A/ 230 V class suitable for
• 180...260 V AC / 1-phase (L1/N)
• 180...260 V AC / 3-phase (L1, L2, L3)
• DC supply 250...370 V DC (++,- -)
++, PB
Braking resistor
U, V, W
Motor
T1, T2
Temperature sensor / switch (see chapter 3.3.6)
Protective earth connection
Permissible cable cross-sections and tightening torques of the terminals
Terminals
L1...W
0.2...6 mm² (AWG 24-10)
T1, T2
0.1...2.5 mm² (AWG 30-14)
3.3.2

Wiring instructions

Absolutely observe the connecting voltage of the KEB COMBIVERT. A 230V-unit will
be immediately destructed on a 400V-power supply.
Never exchange the mains and motor cables.
Some countries demand that the PE-terminal is directly connected to the terminal
box (not over the mounting plate).
Separate supply of the control
Without further cooling measure a separate supply of the control is not permissible
during a longer period, because the interior fan is not controlled here. The occuring
heat accumulation causes an accelerated aging of the capacitors and thus for a
reduction of the economic life time.
GB - 12
--
PB
U
V
W
Perm. conductor cross-section
PE Screw M4
L1
T1
T2
Terminal strip X1A/ 400 V class suitable for
• 305...528 V AC / 3-phase (L1, L2, L3)
• DC supply 420...720 V DC (++,- -)
Tightening torque
0.6 Nm (5 lb inches)
0.6 Nm (5 lb inches)
1.3 Nm (11.5 lb inches)
++
--
L2
L3
PB
U
V
W
T1
T2

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Combivert f5

Inhaltsverzeichnis