Programmierung
Description
Char
Relay alarm output
K
control
depreciated for
MI3 (use the
commands KB
and KH instead of)
Relay alarm output
KB
control
Relay alarm output
KH
control
Bottom
L1O
temperature value
(L)
of output 1
Bottom
L2O
temperature value
of output 2
Output 1 source
O1O
(O)
Output 2 source
O2O
Peak hold time
P
1
Power / AD value Q
setting average / peak / valley / advanced hold cancels all other hold modes
1
136
Format
P B S N Legal Values
K
integer
KB
integer
nKH
integer
float
√ √ L1O= –40.0 or
float
√ √ L2O= –40.0
O1O=1T
float,
or nT,
or nI
O2O=1I
float,
or nT,
or nI
nP
√ √ √ √ 0.0 - 998.9s
float
?nQ
Rev. C1 03/2012
0 = off
1 = on
2 = Target norm.
open
3 = Target norm.
closed
4 = Intern norm.
open
5 = Intern norm.
closed
0 = off
1 = on
2 = norm. open
3 = norm. closed
0 = off
1 = target temp.
2 = head ambient
L= –40.0
v – float value
n – head number
if v = 60 – controlled
by head 1(O1O=1T)
v – float value
n – head number
if v = 60 – controlled
by head 1(O2O=1I)
(999 = ∞)
Factory
Head /
default
Box
2
H
2
B
1
H
0°C
B
0°C
B
O1O=0
B
O2O=0
B
0.0s
H
H