EVS9330 ... EVS9332
(fold-out page on the right)
Position
Description
Controller
Fixing bracket for standard mounting
EMC shield sheet with fixing screws for shielded control cables
Cover with fixing screws
Shield clamp and strain relief for the motor cable
Strain relief for the PE motor cable and the feed cable for the motor temperature monitoring with PTC thermistor
or thermal contact (NC contact)

Connections and interfaces

Position
Description
L1, L2, L3, PE Mains connection
+UG, -UG
DC supply
U, V, W, PE
Motor connection
T1, T2
Connection of PTC thermistor or thermal contact (NC contact) of the motor
X1
AIF interface (automation interface)
Slot for communication module (e. g. XT EMZ9371BC keypad)
X3
Jumper for setting analog input signal at X6/1, X6/2
X4
Terminal strip for system bus (CAN) connection
X5
Terminal strips for connection of digital inputs and outputs
X6
Terminal strips for connection of analog inputs and outputs
X7
Sub-D connector (female) for connection of resolver and KTY temperature sensor of the motor
X8
Sub-D connector (male) for connection of incremental encoder with TTL level or SinCos encoder and KTY
temperature sensor of the motor
X9
Sub-D connector (male) for connection of digital frequency input signal
X10
Sub-D connector (female) for connection of digital frequency output signal
X11
Terminal strip for connection of K

Status displays

Position
LED red
Off
On
Off
Blinking quickly
Blinking slowly
EDKVS9332X DE/EN/FR 2.0
relay output for "safe standstill" (for variants V004 and V024 only)
SR
LED green
Operating status
On
Controller enabled
On
Mains is switched on and automatic start is inhibited
Blinking slowly
Controller inhibited
Off
Undervoltage or overvoltage
Off
Active fault
99