Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze 9300 Montageanleitung Seite 154

Vorschau ausblenden Andere Handbücher für 9300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4
Electrical installation
Basic devices in the power range 15 ... 30 kW
Motor connection
Features of the connection for motor temperature monitoring:
Terminals T1, T2
Connection
Tripping point
Notes
2.5 Nm
T1
22,1 lb-in
T2
4
T1
T2
1
0
Fig.4-12
154
PTC thermistor
– PTC thermistor with defined tripping temperature (acc. to DIN 44081 and
DIN 44082)
Thermal contact (NC contact)
– Temperature switch as NC contact
Fixed (depending on the PTC/thermal contact)
PTC: R
1600
ϑ >
Configurable as warning or error (TRIP)
Monitoring is not active in the Lenze setting.
If you do not use a Lenze motor, we recommend a PTC thermistor up to 150°C.

2
}
PE
+
3
PE
U
V
M 6
U, V, W,
5 Nm
PE
44 lb-in
Motor connection with PTC thermistor or thermal contact (NC contact)
Motor connection with Lenze system cable with integrated control cable for motor
temperature monitoring
Shield sheet
Securely clamp the overall shield and the shield of control cable for motor temperature
monitoring using lugs
Connection of motor cable and separate control cable for motor temperature monitoring
Shield sheet
Securely clamp the shield of the motor cable and the shield of the cable for the motor
temperature monitoring using lugs
PE stud
Connection of PE cable with ring cable lug
U, V, W
Connection of motor cable with ring cable lugs
Observe correct polarity. Observe maximum length of motor cable.
T1, T2 for motor temperature monitoring
Connection of cable for PTC thermistor or thermal contact (NC contact)
Ω
2
2.5 Nm
T1
22,1 lb-in
T2
4
T1
W
T2
1
0
PE
}
PE
+
9300std030
EDKVS9332X DE/EN/FR 2.0

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis