Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze 9300 Montageanleitung Seite 156

Vorschau ausblenden Andere Handbücher für 9300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4
Electrical installation
Basic devices in the power range 15 ... 30 kW
Motor connection
Features of the connection for motor temperature monitoring:
Pins X7/8, X7/9 from resolver input (X7), or
pins X8/8, X8/5 from incremental encoder input (X8)
Connection
Tripping point
Comments
2
T1
1
T2
0
Fig.4-14
Cable cross-sections
9300
Type
EVS9327-xx
EVS9328-xx
EVS9329-xx
156
Linear KTY temperature sensor
Warning: adjustable
Error (TRIP): fixed at 150 °C
Monitoring is not active in the Lenze setting.
The KTY temperature sensor is monitored with regard to interruption and short
circuit.
}
PE
+
3
PE
U
V
M 6
U, V, W,
5 Nm
PE
44 lb-in
Motor connection with KTY thermal sensor
Motor cable
Shield connection
Securely clamp shield of motor cable with the lugs
PE stud
Connection of PE cable with ring cable lug
U, V, W
Connection of motor cable with ring cable lugs
Observe correct polarity. Observe maximum length of motor cable.
2
[mm
]
10
16
25
W
Cable cross-sections U, V, W, PE
9300vec123
[AWG]
8
6
4
EDKVS9332X DE/EN/FR 2.0

Werbung

Inhaltsverzeichnis
loading