Herunterladen Inhalt Inhalt Diese Seite drucken

Terminal Assignment - Lenze 9300 Montageanleitung

Vorschau ausblenden Andere Handbücher für 9300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4
Electrical installation
Wiring of the control connections

Terminal assignment

4.7.5
Terminal assignment
Analog input configuration
Terminal
X6/1, X6/2
1)
Lenze setting (delivery status)
Non-configurable control connections
Terminal
X11/K32
X11/K31
X11/33
X11/34
X5/28
X5/ST1
X5/ST2
Lenze setting of the configurable control connections for the 9300 Servo PLC
Terminal
X5/E1
X5/E2
X5/E3
X5/E4
X5/E5
X5/A1
X5/A2
X5/A3
X5/A4
X6/1, X6/2
X6/3, X6/4
X6/62
X6/63
180
Jumper strip X3
Jumper setting
1)
1-2
6
5
3-4
4
3
2
1
5-6
Description
Function
Safety relay K
Pulse inhibit feedback
SR
1st disconnecting
path
– coil of safety relay K
+ coil of safety relay K
Controller inhibit
Controller enable/inhibit
(DCTRL-CINH)
2nd disconnecting
path
STATE-BUS
Description
Function
Digital inputs
Not assigned
Not assigned
Not assigned
Not assigned
Not assigned
Digital outputs
Not assigned
Not assigned
Not assigned
Not assigned
Analog inputs
Not assigned
Not assigned
Analog outputs
Not assigned
Not assigned
SR
SR
Possible levels
1)
-10 V ... +10 V
-10 V ... +10 V
-20 mA ... +20 mA
Level / state
Open contact: pulse
inhibit is inactive
(operation)
Closed contact: pulse
inhibit is active
Coil is not carrying any
current: active pulse
inhibit
Coil is carrying current:
inactive pulse inhibit
(operation)
LOW: Controller
inhibited
HIGH: Controller enabled
Level
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
HIGH
-10 V ... +10 V
-10 V ... +10 V
-10 V ... +10 V
-10 V ... +10 V
EDKVS9332X DE/EN/FR 2.0