Wiring of the feedback system

4.9.1

Important notes

The feedback signal can either be supplied via input X7 or via input X8.
At X7 a resolver can be connected.
ƒ
At X8 an encoder can be connected.
ƒ
– Incremental encoder TTL
– Sin/cos encoder
– SinCos encoder with serial communication (single-turn or multi-turn)
The resolver or encoder signal for slave drives can be output at the digital frequency output
X10.
Note!
ƒ
ƒ
Installation material required from the scope of supply:
Description
Protective cover
EDKVS9332X DE/EN/FR 2.0
We recommend to use Lenze system cables for wiring.
In the case of self-prepared cables only use cables with shielded cores
twisted in pairs.
Use
Protection for unused Sub-D sockets
Electrical installation
Wiring of the feedback system
Important notes
4
Amount
4
185