Electrical installation
Basic devices in the power range 0.37 ... 11 kW

Important notes

4.3
Basic devices in the power range 0.37 ... 11 kW
4.3.1
Important notes
To gain access to the power connections, remove the covers:
Release the cover for the mains connection with slight pressure on the front and pull
ƒ
it off to the top.
Release the cover for the motor connection with slight pressure on the front and pull
ƒ
it off to the bottom.
Installation material required from the scope of supply:
Description
Shield connection support
Hexagon nut M5
Spring washer ∅ 5 mm (DIN 127)
Serrated lock washer ∅ 5.3 mm
(DIN 125)
Shield sheet
Screw and washer assembly
M4 × 10 mm (DIN 6900)
138
Use
Support of the shield sheets for the supply cable and
motor cable
Fastening of shield connection supports
Shield connections for supply cables, motor cable
Shield sheets fastening
Amount
2
4
2
2
2
4