Herunterladen Inhalt Inhalt Diese Seite drucken

Lenze 9300 Montageanleitung Seite 153

Vorschau ausblenden Andere Handbücher für 9300:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Motor with PTC thermistor or thermal contact (NC contact)
Wire T1, T2 only if the motor is equipped with a PTC thermistor or thermal contact
(NC contact).
An "open" cable acts like an antenna and can cause faults at the drive controller.
ƒ
Danger!
ƒ
ƒ
2.7 k
T1 T2
PES
PES
Fig.4-11
EDKVS9332X DE/EN/FR 2.0
Basic devices in the power range 15 ... 30 kW
All control terminals are only base-insulated (single isolating distance) after
connecting a PTC thermistor or a thermal contact.
Protection against accidental contact in case of a defective isolating
distance is only guaranteed through external measures, e.g. double
insulation.
15 V
7.4 k
3.3 k
MONIT-OH8
PE U
V
W
+UG -UG
PES
PES
J>
PES
M
PE
3~
Circuit diagram of motor connection with PTC thermistor or thermal contact (NC contact) at T1, T2
Electrical installation
Motor connection
4
9300vec139
153

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis