Salicru SPS ADVANCE R2 Betriebsanleitung Seite 54

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

9. ANNEXES.
9.1. GENERAL TECHNICAL SPECIFICA-
TIONS.
Models.
Available power ratings (VA / W).
Technology.
Input.
Input type.
Number of cables.
Rated voltage.
Input voltage range.
Input frequency range.
Inverter.
Waveform.
Power factor.
Rated voltage.
Output voltage accuracy (battery mode).
Total harmonic distortion (THDv), with linear
load.
Frequency.
Transfer time, line mode to battery mode
(normal mode).
Compatibility with APFC loads.
Performance at full load, in normal mode
with battery 100% charged.
Performance at full load, in battery mode.
Overload in line mode
Overload in battery mode.
Batteries (AGM sealed 3 - 5 years life).
Element voltage.
Capacity.
Number of batteries in device connected in
series / group voltage.
Low battery voltage.
Blocking voltage for group end of backup.
Internal battery charger.
Group floating voltage.
Maximum charge current.
Recharge time.
Other functions.
Cold start.
Emergency power off (EPO).
General.
IEC input connectors.
IEC output connectors.
Communication ports.
Connector for external EPO installation
Slot for optional cards.
Monitoring software.
Audible noise at 1 m in battery mode.
Operating temperature.
Storage temperature with batteries.
Storage temperature without batteries.
Working altitude.
Relative humidity.
54
750VA / 450W
With mains absent -backup mode- 50 / 60 ±1% Hz.
> 78 %
> 110 % ±10 % Audible alarm and fault after 1 min
> 110 % ±10 % Audible alarm and fault after 1 min
9 Ah
2 / 12 V DC
11.7 V
10.5 V
13.65 V
1 group of main outputs (2 x IEC 60320 C13)
1 group of programmable outputs (2 x IEC 60320 C13)
ADVANCE R2
1000VA / 600W
Line-interactive with sine-wave output.
Single-phase.
3 cables - Phase R (L) + Neutral (N) and earth.
220 / 230 / 240 V AC
165..290 V AC
50 / 60 Hz (auto-detectable).
Pure sine wave.
0.6
220 / 230 / 240 V AC
±10%
< 5 % linear load
<10 % non-linear load
50 / 60 Hz.
4 ms
Yes
> 95 %
> 120 % ±10 % Immediate fault
> 120 % ±10 % Immediate fault
6 V DC
7 Ah
1 A
4 hours to 90%
Yes
Yes
IEC 60320 C14 10A
1 group of main outputs (4 x IEC 60320 C13)
1 group of programmable outputs (2 x IEC 60320 C13)
(RS232 - DB9).
Yes
SNMP
PowerMaster (free download).
< 40 dB
0..+40ºC
–20..+50 ºC
–20..+70 ºC
2,400 masl (power degradation up to 5,000 m)
0..90 % non-condensing.
1500VA / 900W
> 80 %
9 Ah
4 / 24 V DC
22.2 V
20.5 V
27.5 V
SALICRU