MOD BAT ADV T 2x6AB003 3x40A WCO EE29503
Note related to B1 batteries:
(B1) Device with a more powerful charger, which does
not have a battery pack, nor the possibility of in-
stalling them in the same box.
If an accumulator module is required, it will need to
be ordered as a separate item, which will be con-
nected to the UPS using the supplied cable.
Before connecting a module or group of batteries to the
device or another available module,
check
that the voltage value printed on the back of the
device next to the battery connector is appropriate and
that the polarity between the means of connection cor-
responds.
For more information, see Chapter 9 of this document.
4.3. OPERATING PRINCIPLE.
This user manual describes the installation and mode of operation
of
SPS ADVANCE R2
in Tab. 1 and Tab. 2.
These line-interactive pure sine-wave output devices are de-
signed to protect your most sensitive electronic devices against
power supply problems including undervoltages, spikes, prolonged
voltage drops, line noise and mains failures.
With the device running and the mains supply correct, the load
or loads are powered through the stabiliser featuring buck-boost
technology. Any possible variations in the input voltage are cor-
rected by the stabiliser module while they are within its regulation
range.
With mains supply absent or voltage and/or frequency outside the
range, the load or loads will be powered from the batteries through
the inverter for a certain period of time depending on the model,
battery charge level and load itself connected to the output.
When plugged into an AC socket, the batteries are set to charge
mode regardless of whether the device is on or off.
In
SPS ADVANCE T
crease the standard backup of the devices by connecting additional
modules and/or optimising the recharge time of the accumulators
by incorporating higher performance chargers (B1).
USER MANUAL
it is necessary to
and
SPS ADVANCE T
series UPSs indicated
1000 to 3000 VA models, it is possible to in-
EE
Special customer specifications.
CO
'Made in Spain' marking on UPS and packaging (for customs purposes).
W
Private-label device.
40A
Protection size.
3x
Number of protections in parallel. Omit for one.
003
Last three digits of the battery code.
AB
Initials of the battery family.
6
Number of batteries in one branch.
2x
Number of branches in parallel. Omit for one.
0/
Battery module without them, but with the necessary accesso-
ries to install them.
ADV T
Battery module series.
MOD BAT Battery module.
The entire power range of
bles:
Serial port for communication and control of the device. The
serial port supports communications directly with a server and
the protocol is in accordance with an RS232 interface. This
models also have an additional USB serial port for communi-
cation and control of the device. It is not possible to use the
RS232 and USB ports at the same time.
An EPO connector for optional, external installation by the user
of an emergency stop button.
A smart slot in which one of the following communication
cards can be installed:
Integration into computer networks using an SNMP
ˆ
adapter.
4.3.1. Operating diagram.
AC input
Input
filter
N
N
F
F
Charger
Fig. 7. Operating diagram.
4.3.2. Notable features.
Pure sine-wave output waveform, suitable for all types of load.
Possibility of starting the device without mains power (cold
start).
Great adaptability to the worst conditions of the mains. Wide
input voltage, frequency and waveform ranges, thus avoiding
excessive dependence on limited battery power.
SPS ADVANCE R2
and
T
models ena-
Electronic stabiliser
Output
(buck-boost)
relay
Batteries
Inverter
SPS ADVANCE R2 & T UNINTERRUPTIBLE POWER SUPPLY (UPS)
AC
output
N
N
F
F