Herunterladen Inhalt Inhalt Diese Seite drucken

Api (Accessory); Normal Operation; Operation And Maintenance - Rotoclear C Pro Bedienungsanleitung

Kamera-system mit rotierender sichtscheibe für maschineninnenräume
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

ROTOCLEAR C PRO

API (Accessory)

Rotoclear C Pro provides an API for controlling or
automating by means of external systems via http
or https commands or via a Web-socket connec-
tion.
The API requires a free API license code,
which can be generated in the settings under
"Modules".
The use of the API, the available information
requests, the command overview, and examples
in different programming languages are docu-
mented on our website at rotoclear.com/en/api.
86

Normal operation

In normal operation, the camera head is typically
mounted in the machine interior or in a media-af-
fected environment, and the control unit is typi-
cally mounted in the control cabinet.
The rotor of the camera head rotates at approx.
4,000 rpm and is sealed from the environment by
the supplied sealing air.
In normal operation, the stream can be displayed
on a separate monitor or one associated with the
machine control.
OPERATING MANUAL

Operation and maintenance

During operation of the machine, the
Rotoclear C  Pro must be switched on and the
camera head must be permanently supplied with
sealing air.
Rotor
Do not touch the spinning window while it is
rotating. Risk of minor injuries.
The rotor disk may splinter upon impact or when
encountering external forces. As a result of this,
fragments of the glass disk may be flung outwards
radially and lead to injuries.
When performing tasks which may result in
damage to the disk directly next to the camera
head, keep a safe distance and wear protective
goggles.
The motor must not be permanently blocked
mechanically (e.g. by dirt) and must be able to turn
freely, otherwise the rotor drive may be damaged
(loss of warranty).
In order to ensure safe and damage-free
operation, please also observe the safety and
warranty instructions in the chapters on installa-
tion and commissioning when operating the sys-
tem.
Cleaning
Despite the self-cleaning ability of the spinning
window, the view through it may be impaired over
time due to oil/ cooling lubricant residue or hard
water deposits. Clean the disk at regular intervals
87
with a damp cloth. To do so, draw the cloth care-
fully and slowly from the inside to the outside
using a finger while the motor is running. Repeat
the procedure until the visibility is optimal. If it is
particularly dirty, you can clean the window with
glass cleaner or isopropyl alcohol.
Include the cleaning of the spinning window in
the maintenance plan of your machine. We rec-
ommend weekly cleaning, or more frequently
depending on the environmental conditions.
Please note that when the machine is
switched on, the camera head must also be in
operation and/or the disk must rotate. Only then
can the window clean itself constantly. For a clear
view, it is essential that no medium can make con-
tact with a stationary rotor window and dirty it. In
particular, the vapor from cutting fluids tends to
settle, dry out and leave stains on stationary sur-
faces.
Changing the rotor
Switch off the entire device and let it cool
down for 5 minutes and remove the screw in the
center after the rotor has run out. Remove the
rotor using the supplied suction cup. Do not stick
any tools or objects into the labyrinth gap which
would easily damage the system and invalidate
the warranty.
Risk of cutting damage: when the rotor is
damaged, wear cut-resistant gloves and remove
the screw in the middle after it has coasted to a
standstill. We recommend keeping a replacement
rotor on hand and installing/ cleaning it in alterna-
tion. This ensures a clear view of what is going on
and hence optimal manufacturing conditions at all
times.

Kapitel