• Do not use the product if it is damaged. Never remove
protective devices from the product. This can result in
serious injuries.
• For mitre cuts with an inclined saw table, the parallel
stop should be placed on the lower part of the saw ta-
ble.
ATTENTION
Secure long workpieces against tipping at the end of
the cutting process (e.g. with a roller stand or similar).
• Keep your hands at a safe distance from the band
saw blade. Use a push stick for narrow cuts.
• Store the push stick on the holder provided for it on
the product so that you can reach it from your normal
working position and always have it to hand.
• Switch the product off if it is not in use.
• In the normal working position, the operator is in front
of the product.
Residual risks
The product has been built according to state-of-the-
art and the recognised technical safety rules.
However, individual residual risks can arise during
operation.
• Residual risks can be minimised if the "Safety Instruc-
tions" and the "Intended Use" together with the oper-
ating manual as a whole are observed.
• Use the product in the way that is recommended in
this operating manual. This is how to ensure that your
product provides optimum performance.
• Furthermore, despite all precautions having been met,
some non-obvious residual risks may still remain.
• Keep your hands away from the working area when
the product is in operation.
• Damage to hearing if the stipulated hearing protection
is not worn.
• Damage to the lungs if the stipulated respiratory pro-
tection is not worn.
• Risk of injury from tools thrown away due to improper
holding or guiding.
• Health hazard due to electrical power, with the use of
improper electrical connection cables.
• Avoid accidental start-up of the product: when insert-
ing the plug into the socket, do not press the on/off
switch.
• Before performing setting or maintenance work, re-
lease the on/off switch and pull out the mains plug.
WARNING
This power tool generates an electromagnetic field
during operation. This field can impair active or passive
medical implants under certain circumstances. In order
to prevent the risk of serious or deadly injuries, we rec-
ommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the power tool.
32 | GB
WARNING
In case of extended working periods, the operating per-
sonnel may suffer circulatory disturbances in their
hands (vibration white finger) due to vibrations.
Raynaud's syndrome is a vascular disease that causes
the small blood vessels on the fingers and toes to
cramp in spasms. The affected areas are no longer
supplied with sufficient blood and therefore appear ex-
tremely pale. The frequent use of vibrating products can
cause nerve damage in people whose circulation is im-
paired (e.g. smokers, diabetics).
If you notice unusual adverse effects, stop working im-
mediately and seek medical advice.
6
Technical data
AC motor
Power consumption
Idle speed n
Band saw blade length
Band saw blade width
Max. band saw blade width
Band saw blade speed
Cut height
Swing
Saw table size
Saw table size with extension
Inclinable saw table
Max. workpiece size
Cable length
Weight
Subject to technical changes!
*Operating mode S1 (continuous operation)
The product can be operated continuously with the speci-
fied power.
**Operating mode S2 (short-term operation)
The product may only be operated at the specified power
for a brief time (20 min.).
The workpiece must have a minimum height of 3 mm
and a minimum width of 10 mm.
Noise data
WARNING
Noise can have serious effects on your health. If the
machine noise exceeds 85 dB, please wear suitable
hearing protection for you and persons in the vicinity.
The noise and vibration values have been determined in
accordance with EN 62841.
Sound pressure level L
Uncertainty K
Sound power level L
Uncertainty K
www.scheppach.com
550 Watt (S2 20min**)
0
pA
pA
wA
wA
230 - 240V~ 50 Hz
370 Watt (S1*)
1480 rpm
1790 mm
6 mm
13 mm
720/1000 m/min
130 mm
245 mm
307 x 315 mm
315 x 520 mm
0° - 45°
580x400x130 mm
1800 mm
approx. 22 kg
73 dB
3 dB
86 dB
3 dB