22.3.2 Pin Assignment
The control voltage for Emergency Stop and the enabling switch is 24 V DC.
The cable assignment is shown in the table below:
Core color
Purple
Black
Yellow
Green
Pink
Grey
Brown
White
Red
Blue
Table 22: Pin assignment
Electrical characteristics
Emergency Stop
Enabling Switch
Tablet Supply
Voltage accuracy
Table 23: Electrical characteristics
23 Commissioning of the M2Smart
23.1 Selecting a Suitable Power Supply for Charging the Tablet
The charging voltage and current depend on the tablet used and the length of the connection cable.
Lenovo Tab M10 Full HD Plus & Huawei MatePad SE
Cable length
5-m connection cable
10-m connection cable
Table 24: Charging voltage and current for Lenovo Tab M10 Full HD Plus & Huawei MatePad SE
Samsung Galaxy Tab A7 & Samsung Galaxy Tab A8
Cable length
5-m connection cable
10-m connection cable
Table 25: Charging voltage and charging current for Samsung Galaxy A7 & Samsung Galaxy Tab A8
Samsung Galaxy Tab S8
Cable length
5-m connection cable
10-m connection cable
Table 26: Charging voltage and charging current for Samsung Galaxy S8
®
M2Smart
HMI Case_Bedien- Projektierhandbuch_Operating Project Engineering Manual_V1.06_de_en
Signal name
+U
-U
SI_Enable_1_in
SI_Enable_1_Out
SI_Enable_2_In
SI_Enable_2_Out
SI_Stop_1_In
SI_Stop_1_Out
SI_Stop_2_In
SI_Stop_2_Out
®
HMI Case
Charge voltage
+ 5.5 V DC
+ 5.5 V DC
Charge voltage
+ 5.5 V DC
+ 5.5 V DC
Charge voltage
+ 5.5 V DC
+ 5.5 V DC
Function
+ U charging voltage
- U charging voltage
Enabling switch Input 1
Enabling switch Output 1
Enabling switch Input 2
Enabling switch Output 2
Emergency Stop input 1
Emergency Stop output 1
Emergency Stop input 2
Emergency Stop output 2
Volt (dc)
35 V
30 V
5.5 – 6 V
±10 %
Charge current
Approx. 1.1 A
Approx. 0.7 A
Charge current
Approx. 1.2 A
Approx. 0.7 A
Charge current
Approx. 1.0 A
Approx. 0.6 A
Ampere (A)
2.0 (resistive)
1.0 (resistive)
0.7 (inductive)
2.0
57 / 64