Herunterladen Diese Seite drucken

HBM PMX Bedienungsanleitung Seite 305

Vorschau ausblenden Andere Handbücher für PMX:

Werbung

Name
Get SystemeventBool­
Count
Name
Get SystemeventByte
idx
PMX
Function: GetSystemeventBoolCount
This function is only valid in context of a Task ­> External
Event ­> System Event. The number of arguments de­
pends on the type of the signal determined by the get­
SystemeventNr function. This function returns the avail­
able number "BOOL"­type arguments for the current
systemevent. Every PMX device carries a xml file de­
scribing the valid systemevents to be retrieved via
http://pmx/data/systemevent.xml.
Data
Inherited
type
from
BYTE
Function: GetSystemeventByte
This function is only valid in context of a Task ­> External
Event ­> System Event. The number of arguments de­
pends on the type of the signal determined by the get­
SystemeventNr function. This function returns the n­th
argument of type "BYTE" for the corresponding
systemevent. Every PMX device carries a xml file de­
scribing the valid systemevents to be retrieved via
http://pmx/data/systemevent.xml.
Data type Inherited
from
BYTE
DINT
A3257-5.1 HBM: public
CODESYS‐V3 Soft PLC (WGX001 only)
Adress Initial
Adress Initial
Comment
value
Comment
value
Index value of
the n‐th Byte of
the systemevent.
Possible values:
0<=idx<5 and
idx<>
303