Herunterladen Diese Seite drucken

HBM PMX Bedienungsanleitung Seite 24

Vorschau ausblenden Andere Handbücher für PMX:

Werbung

PMX product description
22
The following types of plug-in card are available:
PX401
S The PX401 measurement card offers four individually
configurable current or voltage inputs with TEDS
sensor detection.
S Extreme accuracy is guaranteed, as all the channels
have their own A/D converter with 24-bit resolution.
This also allows the acquisition of all the channels to
be totally synchronized.
PX455
S The PX455 measurement card is available for
measurement with strain gages (SG) and also has
four channels with 24-bit resolution and TEDS sensor
detection.
S The measurement card is suitable for strain gages in
both half bridge and full bridge circuits, as well as for
inductive transducers in half bridge and full bridge
circuits, LVDTs and potentiometric sensors.
PX460
S The frequency measurement card PX460 can be used
to operate torque flanges (torque, speed, angle of
rotation), angle/incremental encoders, SSI/PWM
sensors and frequency measurements up to 2 MHz.
Channels 1 and 3: Frequency measurement (fixed)
Channels 2 and 4: Frequency (digital, inductive),
counter, encoder, SSI, PWM (adjustable)
A3257-5.1 HBM: public