BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
7
System Functions (continued)
7.9
Parameter Manager
7.9.1
Description
The parameter manager is responsible for the saving of
parameters in the permanent memory of the device. On
startup, all stored parameters are read from permanent
memory; if parameters are changed, the data is stored
within the permanent memory by the parameter manager.
All data is protected with a CRC32 checksum. In the event
of damaged memory, the parameter manager outputs the
Parameters not consistent event.
7.9.2
Events
Event Code
Event Type
0x8D24 (36132)
Warning
0x8D25 (36133)
Error
0x8D26 (36134)
Warning
Tab. 7-30: Parameter manager – Events
88
english
Event – Description – Remedy
Parameter write error – for information purposes
only.
Parameters not consistent – basic settings are
used, service required. Parameterization
processes and resets can no longer be
performed.
User data was reset to the default settings.
► Check settings and acknowledge warning.
Device Status
0 – Device is operating properly.
4 – Failure
1 - Maintenance required