Secondary Device Functions (continued)
Device Temperature
Device Temperature contains information about the device
temperature (current value in °C), the minimum or
maximum device temperature since the last time the
device was switched on/reset (in °C) and minimum or
maximum device temperature during the lifetime of the
device (in °C).
Device Temperature Alarm Configuration
Setting of the lower threshold value (in °C) for the device
temperature warning (0x8D20) and of the upper threshold
value (in °C) for the device temperature warning (0x8D10).
6.9.4
Events
Event Code
Event Type
0x4000 (16384)
Error
0x4210 (16912)
Warning
0x4220 (16928)
Warning
0x8D10 (36112) Warning
0x8D20 (36128) Warning
Tab. 6-46: Internal temperature – Events
6.9.5
Variant Dependence
The functionality is available in all variants.
70
english
Event – Description – Remedy
Temperature Fault – Overload – The device is operated
outside of the device-specific temperature limits. Risk of
device damage.
Device Temperature Overrun – Clear Heat Of Source
– Risk of device damage. The device is too hot.
► Remove heat source, provide the device with heat
insulation if necessary.
Device Temperature Underrun – Insulate Device – Risk
of device damage. The device is too cold.
► Insulate the device.
Device Temperature Upper Warning – The set upper
temperature warning threshold has been exceeded.
Device Temperature Lower Warning – The device
temperature has fallen below the set lower temperature
warning threshold.
Device Status
4 – Failure
2 – Out-of-Specification
2 – Out-of-Specification
0 – Device is operating
properly.
0 – Device is operating
properly.