BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
3
Overview of IO-Link Data and Functions (continued)
Name
Index
Teach-in Select
0x003A
Teach-in Result
0x003B
SSC 1 Parameter
0x003C
Setpoint 1
Setpoint 2
SSC 1 Configuration
0x003D
Switchpoint Logic
Switchpoint Mode
Switchpoint Hysteresis
SSC 2 Parameter
0x003E
Setpoint 1
Setpoint 2
SSC 2 Configuration
0x003F
Switchpoint Logic
Switchpoint Mode
Switchpoint Hysteresis
SSC 3 Parameter
0x4000
(16384)
Setpoint 1
Setpoint 2
SSC 3 Configuration
0x4001
(16385)
Switchpoint Logic
Switchpoint Mode
Switchpoint Hysteresis
SSC 4 Parameter
0x4002
(16386)
Setpoint 1
Setpoint 2
SSC 4 Configuration
0x4003
(16387)
Switchpoint Logic
Switchpoint Mode
Switchpoint Hysteresis
Transducer Value
0x01B2
(434)
www.balluff.com
Subindex
Access
Switching profiles [LSSC]
0
R/W
(58)
0
R
(59)
0
R/W
(60)
1
R/W
2
R/W
0
R/W
(61)
1
R/W
2
R/W
3
R/W
0
R/W
(62)
1
R/W
2
R/W
0
R/W
(63)
1
R/W
2
R/W
3
R/W
0
R/W
1
R/W
2
R/W
0
R/W
1
R/W
2
R/W
3
R/W
0
R/W
1
R/W
2
R/W
0
R/W
1
R/W
2
R/W
3
R/W
0
R
Length
Data Type
1 byte
UINT8
1 byte
UINT8
8 bytes
4 bytes
INT32
4 bytes
INT32
4 bytes
1 byte
UINT8
1 byte
UINT8
2 bytes
INT16
8 bytes
4 bytes
INT32
4 bytes
INT32
4 bytes
1 byte
UINT8
1 byte
UINT8
2 bytes
INT16
8 bytes
4 bytes
INT32
4 bytes
INT32
4 bytes
1 byte
UINT8
1 byte
UINT8
2 bytes
INT16
8 bytes
4 bytes
INT32
4 bytes
INT32
4 bytes
1 byte
UINT8
1 byte
UINT8
2 bytes
INT16
4 bytes
INT32
Data
Default
Storage
No
0x00
n/a
Yes
No
0x7FFF FFFC
(deactivated)
No
0x7FFF FFFC
(deactivated)
Yes
No
0x00
No
0x01
No
0x96
Yes
No
0x7FFF FFFC
(deactivated)
No
0x7FFF FFFC
(deactivated)
Yes
No
0x00
No
0x01
No
0x96
Yes
No
0x7FFF FFFC
(deactivated)
No
0x7FFF FFFC
(deactivated)
Yes
No
0x00
No
0x01
No
0x96
Yes
No
0x7FFF FFFC
(deactivated)
No
0x7FFF FFFC
(deactivated)
Yes
No
0x00
No
0x01
No
0x96
n/a