Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 131

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
5
Primary Device Functions (continued)
5.4.5
System Commands
Command Value Device Action
0xE0 (224)
Teach Preset – Sets the current
measurement value to the value of
Measurement Preset.
0xE1 (225)
Teach Lower Limit – Sets the lower
end of the measuring range.
0xE2 (226)
Teach Upper Limit – Sets the upper
end of the measuring range.
Tab. 5-22: Measurement profiles – System Commands
For an overview of all System Commands, see section 3.5
on page 21.
5.4.6
Events
Event Code
Event Type
0x8D00 (36096)
Warning
0x8D01 (36097)
Warning
0x8D02 (36098)
Warning
0x8D03 (36099)
Warning
0x8D04 (36100)
Warning
0x8D05 (36101)
Warning
Tab. 5-23: Measurement profiles – Events
5.4.7
Variant Dependence
The functionality is available in all variants.
www.balluff.com
Event – Description – Remedy
The measurement value is below the
measurement range.
Accuracy cannot be guaranteed.
The measurement value is above the
measurement range.
Accuracy cannot be guaranteed.
The measurement value is below the detection
range; no measurement value can be determined.
► Check application.
The measurement value is above the detection
range; no measurement value can be determined.
► Check application.
No measurement value can be determined.
► Check application.
Measurement error/redundancy check failed.
► Check application.
Device Status
2 – Out of Specification
2 – Out of Specification
2 – Out of Specification
2 – Out of Specification
2 – Out of Specification
2 – Out of Specification
english