Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 175

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
7
System Functions (continued)
7.7.2
ISDU
Name
Index
Process Data Profile
0x0051 (81)
selection
Process Data Input
0x000E (14)
Descriptor
Process Data
0x000F (15)
Output Descriptor
Last Valid Process
Data Inputs
Smart Sensor
0x0028 (40)
Profile Ed. 2
Comprehensive
0x0028 (40)
Condition
Monitoring
Last Valid Process
0x0029 (41)
Data Outputs
Tab. 7-20: Process data info and configuration – ISDU
PD Profile Selection
The available profile is selected automatically when the
device variant is selected. One profile exists for each
selected device variant.
PD Configuration ID Name
0x00 (0)
Empty
0x01 (1)
Smart Sensor Profile Ed. 2
0x03 (3)
Smart Sensor Profile (CCM)
Tab. 7-21: Process data info and configuration – PD Profile Selection
If the variant of the device is changed, the currently set
profile is retained. In the case that the corresponding PD
profile is not valid for this variant, the default profile for the
corresponding variant is selected.
This case is also indicated by a diagnostic message.
www.balluff.com
Subindex
Access
Length
0
R/W
1 byte
0
R
= PD input
data length
0
R
= PD output
data length
0
R
6 bytes
0
R
10 bytes
0
R
Description
Empty profile. Is used as a shared fallback profile, if profile
configuration was not successful.
Measuring profile
Measuring profile with CCM Stats bits
Data Type
Data
Storage
UINT8(ENUM)
UINT8[]
UINT8[]
0
Default
Yes
1 (Smart Sensor
Profile Ed. 2)
n/a
n/a
n/a
n/a
n/a
english
83

Werbung