Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 163

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
7
System functions
7.1
Device Status and Detailed Device Status
7.1.1
Description
The Device Status feature provides information about the
current device status.
Each Device Status is combined with a corresponding
diagnostic message (Events see chapter 3.6 on
page 22).
It is also possible to actively read out current pending
events of the device.
7.1.2
Process Data
Object ID
Name
0x002F (47)
System Error
Tab. 7-1:
Device Status and detailed Device Status – Process Data
Also see section Process Data Profiles on page 10.
7.1.3
ISDU
Name
Device Status
0x0024 (36)
Detailed Device Status
0x0025 (37)
Tab. 7-2:
Device status and detailed device status – ISDU
www.balluff.com
Description
This bit is set (TRUE) if there is an error in the device. This information is
linked to the device status (4-Failure), which can be triggered by different
device functions or diagnostic messages. The bit is reset as soon as the
error status is no longer displayed (FALSE).
Index
Subindex
Access
0
0
Length
Data Type
R
1 byte
UINT8
R
30 bytes
UINT8[]
Direction
Input
Data Storage
Default
n/a
n/a
0x00 0x00 ...
0x00
english
71

Werbung

loading