Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 110

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
3
Overview of IO-Link Data and Functions (continued)
Name
Boot Cycle Counter
Boot Cycle Counter
Custom Boot Cycle
Counter
Voltage Monitoring
Detection Time
Duration
Device Temperature
Device Temperature
Minimum Device
Temperature Since
Reset
Maximum Device
Temperature Since
Reset
Lifetime Minimum
Device Temperature
Lifetime Maximum
Device Temperature
Device Temperature
Alarm Configuration
Lower Alarm Level
Device Temperature
Upper Alarm Level
Device Temperature
Device Status
Detailed Device Status
Diagnosis Level
Configuration
Event Code
Suppression
Event Code
Suppression
Event Code
Suppression Teach-in
Event Code
Suppression Delete
System Commands
18
english
Index
Subindex
Access
Boot Cycle Counter
0x0058
0
R
(88)
1
R
2
R
Voltage and Current Monitoring
0x2200
0
R/W
(8704)
Internal Temperature
0x0052
0
R
(82)
1
R
2
R
3
R
4
R
5
R
0x0053
0
R/W
(83)
1
R/W
2
R/W
Device Status and Detailed Device Status
0x0024
0
R
(36)
0x0025
0
R
(37)
Diagnosis Suppression
0x0070
0
R/W
(112)
0x0071
0
R/W
(113)
1...5
R/W
0x0072
0
W
(114)
0x0073
0
W
(115)
Reset Commands
0x0002
0
W
(2)
Length
Data Type
8 bytes
4 bytes
UINT32
4 bytes
UINT32
2 bytes
UINT16
10 bytes
2 bytes
INT16
2 bytes
INT16
2 bytes
INT16
2 bytes
INT16
2 bytes
INT16
4 bytes
2 bytes
INT16
2 bytes
INT16
1 byte
UINT8
30 bytes
UINT8[]
1 byte
UINT8(ENUM)
10 bytes
2 bytes
UINT16
2 bytes
UINT16
2 bytes
UINT16
1 byte
UINT8
Data
Default
Storage
n/a
n/a
n/a
Yes
10
n/a
n/a
n/a
n/a
n/a
n/a
Yes
No
0
No
85
n/a
n/a
0x00 0x00 ...
0x00
Yes
0
Yes
No
0
n/a
n/a
n/a

Werbung

loading