Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 172

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
7
System Functions (continued)
Value
Name
Analog Output
0x0006 (6)
Switching Counter Value
0x0013 (19)
Switching Speed Value
0x0028 (40)
MDC Value High Resolution
0x002A (42)
MDC Scale
Tab. 7-15: Pin assignment – Signal Source
Logic
With Logic, the input/output can be configured as inverted
or normal.
Value
Name
0x00 (0)
Normal
0x01 (1)
Inverted
Tab. 7-16: Pin assignment – Logic
Characteristic
With Characteristic, a rising or falling characteristic of the
analog output can be configured.
Value
Name
0x00 (0)
Rising
0x01 (1)
Falling
Tab. 7-17: Pin assignment – characteristic
Type
The output can be configured with Type.
Value
Name
Digital
0x00 (0)
PNP
0x01 (1)
NPN
0x02 (2)
Push-Pull
Analog
0x00 (0)
4...20mA
0x03 (3)
0...10V
Tab. 7-18: Pin assignment – Type
7.5.3
System Commands
For an overview of all System Commands, see section 3.5
on page 21.
80
english
Description
Non-inverting logic
Inverted logic
Description
Rising input value = Rising output value
Rising input value = Falling output value
Description
PNP output
NPN output
Push-Pull output
Analog current output 4 to 20mA
Analog voltage output 0 to 10V

Werbung

loading