Herunterladen Diese Seite drucken

Balluff BFD 3SAP-19N000-U01-LA2-C Serie Konfigurationsanleitung Seite 140

Ultraschall-sensoren

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFD 3SAP-19N000-U01-LA2-C_ _ _ _ _
Ultrasonic sensors
6
Secondary Device Functions (continued)
Switching Speed Monitoring Input
With Switching Speed Monitoring Input, the internal binary
signal source can be selected. Input contains a list of the
internal binary signals.
Value
Name
0x0001 (1)
Digital Input Pin 4
0x0002 (2)
Digital Input Pin 2
0x0003 (3)
Switching Counter Limit not reached
0x0004 (4)
Switching Counter Limit reached
0x0005 (5)
Switching Counter Limit exceeded
0x0008 (8)
Signal Delay Channel 1
0x0009 (9)
Signal Delay Channel 2
0x000A (10)
Signal Delay Channel 3
0x000B (11)
Signal Delay Channel 4
0x0010 (16)
Switching speed OK
0x0011 (17)
Switching Speed too low
0x0012 (18)
Switching Speed too high
0x0015 (21)
Short Circuit Pin 4
0x0016 (22)
Short Circuit Pin 2
0x0017 (23)
Undervoltage
0x0018 (24)
Overvoltage
0x0019 (25)
Cable Break Pin 4
0x001A (26)
Cable break pin 2
0x0021 (33)
Signal Quality Bad
0x002B (43)
Measurement Error
0x002C (44)
MDC Out of Measurement Range
Warning
0x002F (47)
System Error
0x003A (58)
LSSC1
0x003B (59)
LSSC2
0x003C (60)
LSSC3
0x003D (61)
LSSC4
0x0043 (67)
Overload Pin 4
0x0044 (68)
Overload Pin 2
0x0063 (99)
Logic Block 1 Result
0x0064 (100)
Logic Block 2 Result
0x0065 (101)
Logic Block 3 Result
0x0066 (102)
Logic Block 4 Result
Tab. 6-9:
Signal Speed Monitoring – Switching Speed Monitoring
Input
48
english
Switching Speed Monitoring Mode
With Switching Speed Monitoring Mode, the current mode
of the counter function can be selected.
Value
Meaning
Description
0x00 (0) Deactivated
Deactivated
0x01 (1) Speed
Speed monitoring
Tab. 6-10: Signal Speed Monitoring – Speed Monitoring Mode
Speed Upper Limit High
In combination with Speed Upper Limit Low, it forms a
threshold value with hysteresis for the too high status.
Speed Upper Limit Low
In combination with Speed Upper Limit High, it forms a
threshold value with hysteresis for the too high status.
Speed Lower Limit High
In combination with Speed Lower Limit Low, it forms a
threshold value with hysteresis for the too low status.
Speed Lower Limit Low
In combination with Speed Lower Limit High, it forms a
threshold value with hysteresis for the too low status.
Speed Monitoring Startup Delay
With Startup Delay, the time for the startup delay can be
set. The startup delay begins after the supply voltage is
switched on. During the startup delay, speed monitoring
has no function. Speed monitoring starts after the startup
delay has elapsed. The value represents the time in
seconds. The value range is between 0x00 (0) and 0xFF
(255). A value of 0x00 (0) represents no start delay.

Werbung